Three-phase modular, data centre flagship

Eaton 93PM Three-Phase UPS, Service, Battery & Quote Canada

The Eaton 93PM is Eaton's flagship three-phase modular UPS, 15 to 200+ kW with hot-swappable power modules that scale capacity without shutdown. Deployed in Canadian data centres, hospitals, and government facilities where uptime is non-negotiable. We provide battery string replacement, power module service, preventive maintenance, and new system quotes across Canada.

Three phaseclass
Onlinetopology
24/7emergency line

How an online unit protects the load

AC INPUTutility supplyRECTIFIERAC to DCDC BUSregulated DCINVERTERDC to clean ACPROTECTED LOADservers, controlsBATTERYon the DC busSTATIC BYPASSmaintenance and overload pathNo transfer gap: the load neverleaves the inverter.

Double conversion: the load always runs on the inverter, so an outage produces no transfer gap. The static bypass exists for maintenance and overload, not for everyday sags.

UPS Service Canada is not affiliated with Eaton Corporation®

Technical Specifications

Eaton 93PM, Three-Phase Modular UPS

Output capacity
15 to 200+ kW (scalable via hot-swap modules)
Topology
Online double-conversion, modular
Architecture
Hot-swappable power modules (15/25/50 kW each)
Input voltage
208V or 480V (3-phase)
Output voltage
208V or 480V (3-phase)
Efficiency
Up to 97.4% (double-conversion) / 99% (ESS mode)
Transfer time
Zero (true online)
Redundancy
N+1 internal, 2N system-level
Battery
VRLA battery strings (external cabinet)
Management
Touchscreen LCD, Gigabit NIC, SNMP, Modbus, BACnet
Footprint
As low as 0.46 m² for 200 kW (industry-leading density)
Warranty
5-year Eaton (extended available)

Orderable configs

Eaton 93PM models we quote and service

Rows below are the complete model / rating / voltage / part-number lines from the sourced Eaton family table. Incomplete rows (blank rating or part number) are omitted.

Model Rating Phase / Voltage Part number Status
Eaton 93PM 30kW (50kW frame) 30 3ph+N+PE in/out 220/380-240/415V 93PM-30(50) Current
Eaton 93PM 40kW (50kW frame) 40 3ph+N+PE in/out 220/380-240/415V 93PM-40(50) Current
Eaton 93PM 50kW (50kW frame) 50 3ph+N+PE in/out 220/380-240/415V 93PM-50(50) Current
Eaton 93PM 60kW (100kW frame) 60 3ph+N+PE in/out 220/380-240/415V 9PG06P0009E20R2 Current
Eaton 93PM 80kW (100kW frame) 80 3ph+N+PE in/out 220/380-240/415V 93PM-80(100) Current
Eaton 93PM 100kW (100kW frame) 100 3ph+N+PE in/out 220/380-240/415V 93PM-100(100) Current
Eaton 93PM 90kW (150kW frame) 90 3ph+N+PE in/out 220/380-240/415V 93PM-90(150) Current
Eaton 93PM 120kW (150kW frame) 120 3ph+N+PE in/out 220/380-240/415V 93PM-120(150) Current
Eaton 93PM 150kW (150kW frame) 150 3ph+N+PE in/out 220/380-240/415V 93PM-150(150) Current
Eaton 93PM 120kW (200kW frame) 120 3ph+N+PE in/out 220/380-240/415V 93PM-120(200) Current
Eaton 93PM 160kW (200kW frame) 160 3ph+N+PE in/out 220/380-240/415V 93PM-160(200) Current
Eaton 93PM 200kW (200kW frame) 200 3ph+N+PE in/out 220/380-240/415V 93PM-200(200) Current

Source: https://threephaseups.ca/eaton/93pm/. 12 complete rows.

Request a Quote

Eaton 93PM quote, service, batteries, modules, or new system

Quote back within one business day. Includes site assessment for three-phase installations.

Include in your email:

  • What you need: battery string replacement / power module service / PM contract / new 93PM quote
  • 93PM model, capacity (kW), serial (e.g. 93PM 100kW, SN: GV12345678)
  • Battery age, module count, alarm codes, capacity expansion needs
  • Site location, maintenance frequency, access requirements

Related Eaton Three-Phase

Compare Eaton three-phase UPS

Eaton 9PX

Capacity: 700 VA to 11 kVA

View Eaton 9PX →

Eaton 93PM ✔

Capacity: 15 to 200+ kW modular

View Eaton 93PM ✔ →

Eaton 9395P

Capacity: 200 to 1,200 kW

View Eaton 9395P →

FAQ

Eaton 93PM questions

Can 93PM power modules be replaced without downtime?
Yes. The 93PM’s modular architecture allows hot-swappable power modules, a failed or end-of-life module can be removed and replaced while the remaining modules continue protecting the load. This is the defining advantage of the 93PM over non-modular three-phase UPS platforms like the Eaton 9395. No maintenance bypass required for module-level service.
How often should 93PM batteries be replaced?
VRLA battery strings in the 93PM typically last 3 to 5 years depending on ambient temperature and discharge events. At three-phase loads, batteries discharge more deeply per event than single-phase, accelerating wear. We recommend impedance testing at 2.5 years and proactive replacement at 3 to 4 years for mission-critical installations. The 93PM G2 also supports lithium-ion batteries with 10+ year design life.
93PM vs 9395P, which should I choose?
The 93PM is modular (15/25/50 kW hot-swappable modules) and scales from 15 to 200+ kW. The 9395P is monolithic (200 to 1,200 kW) for large-capacity installations. If you need modular redundancy, pay-as-you-grow scalability, and hot-swap module service, the 93PM is the right platform. If you need 200+ kW in a single frame without modular architecture, the 9395P is the choice.
Can you install a new 93PM in a Canadian data centre?
Yes. We quote the unit, delivery, rigging, electrical installation, commissioning, and ongoing maintenance as a single project. For data centre environments, we coordinate with your facilities team, MEP engineer, and NOC for scheduled installation windows. Three-phase installation requires coordination with a licensed electrician, we manage the entire process.
Do you service 93PM systems in government secure facilities?
Yes. We hold active federal contracts including the House of Commons and service Eaton 93PM systems in federal government data centres, DND facilities, and provincial government installations. Our technicians undergo security clearance processes and comply with facility-specific access protocols.

Where can you buy an Eaton 93PM in Canada?

The Eaton 93PM is sold in Canada through Eaton’s distribution channel and through independent power suppliers who quote the unit as part of a complete installation. Buying the frame on its own is rarely useful: a three-phase UPS needs sizing, rigging, electrical tie-in by a licensed electrician and commissioning before it protects anything. We quote 93PM systems Canada-wide as a single project covering the unit, delivery, installation, commissioning and ongoing maintenance.

What a 93PM quote should include

  • Frame size and module count. The 93PM scales in hot-swappable power modules. Specify the load you have today and the redundancy you want, since an N+1 configuration adds one module beyond what the load alone requires.
  • Battery runtime. Cabinet count drives both the price and the floor space. VRLA strings are the default; the 93PM G2 also accepts lithium-ion, which costs more up front and lasts considerably longer.
  • Installation scope. Rigging, electrical connection and commissioning are usually a larger line item than first-time three-phase buyers expect.
  • Service coverage after commissioning. Response time, preventive maintenance frequency and parts availability matter more over the unit’s life than the purchase price does.

Lead times on three-phase frames move with Eaton’s production schedule, so confirm the quoted delivery window before you commit to a cutover date. For nationwide three-phase installation and maintenance coverage, a nationwide UPS service network services Eaton and Powerware systems across Canada.