Online double-conversion, tower form factor

Eaton 9SX UPS, Service, Battery & Quote Canada

The Eaton 9SX delivers 700 VA to 11 kVA of true online double-conversion power in a tower form factor. Built for environments where rack mounting isn't practical, executive offices, hospital bedside, lab benches, and floor-standing server rooms. ABM battery management, Energy Saver System, and optional EBMs for extended runtime.

Onlinedouble conversion
Rack or towerformat
24/7emergency line

How an online unit protects the load

AC INPUTutility supplyRECTIFIERAC to DCDC BUSregulated DCINVERTERDC to clean ACPROTECTED LOADservers, controlsBATTERYon the DC busSTATIC BYPASSmaintenance and overload pathNo transfer gap: the load neverleaves the inverter.

Double conversion: the load always runs on the inverter, so an outage produces no transfer gap. The static bypass exists for maintenance and overload, not for everyday sags.

UPS Service Canada is not affiliated with Eaton Corporation®

Technical Specifications

Eaton 9SX, Online Tower UPS

Output capacity
700 VA to 11 kVA (model-dependent)
Topology
Online double-conversion (VFI)
Form factor
Tower (primary), some models convertible
Input voltage
120V or 208V (model-dependent)
Output voltage
120V or 208V (configurable)
Efficiency
Up to 95% (online) / 99% (Energy Saver System)
Transfer time
Zero (true online)
Battery
HotSwap internal + optional EBMs
Management
LCD, USB, serial, network card slot (optional)
ABM technology
Advanced Battery Management, extends life up to 50%
Warranty
5-year Eaton (battery: 2 years)

Request a Quote

Eaton 9SX quote, battery, new unit, or service

Email us your details, we quote units, batteries, installation, and service contracts. Quote back within one business day.

Include in your email:

  • What you need: Battery replacement (HotSwap) / New 9SX unit / Extended Battery Module (EBM) / Service / maintenance contract
  • Model (or serial number for battery matching)
  • Quantity and delivery postal code
  • Battery age? Alarm codes? EBM needed? Floor-standing or wall-adjacent?

Related Eaton Models

Compare Eaton online UPS

Eaton 5PX

Capacity: 750 to 3000 VA

View Eaton 5PX →

Eaton 9SX ✔

Capacity: 700 VA to 11 kVA

View Eaton 9SX ✔ →

Eaton 9PX

Capacity: 700 VA to 11 kVA

View Eaton 9PX →

FAQ

Eaton 9SX questions

Eaton 9SX vs 9PX, what is the difference?
Same online double-conversion topology, same ABM battery management, same efficiency. The key difference is form factor: the 9SX is designed as a tower unit (floor-standing), while the 9PX is designed as a rack-mount unit (2U, convertible to tower). If your deployment is rack-based, choose the 9PX. If it’s floor-standing or beside equipment, the 9SX is the better fit.
Can I replace the 9SX battery without shutting down?
Yes. Eaton’s 9SX manual says the batteries can be replaced without turning off the UPS or disconnecting the load, and warns not to disconnect them while the UPS is in Battery mode. The swap is not done on bypass: in Bypass mode, Eaton says, the equipment is not protected (see Eaton UPS on bypass: what it means and what to check). The manual asks for qualified service personnel knowledgeable of batteries.
Is the 9SX suitable for a hospital environment?
Yes. The 9SX tower form factor is commonly deployed beside medical devices, in hospital bedside applications, and in lab environments where rack infrastructure doesn’t exist. The online double-conversion topology provides the zero-transfer-time protection required for sensitive medical equipment.
Can I add extended runtime to the 9SX?
Yes. The 9SX supports External Battery Modules (EBMs) connected to the rear panel. Each EBM adds approximately 10 to 20 minutes of runtime at half load. Up to 4 EBMs can be stacked vertically beside the main unit.
What warranty does the 9SX come with?
Warranty terms come from Eaton for each purchase; check them for your serial number. Eaton’s 9SX manual notes that the warranty is void if deep discharge protection is disabled.

Size a unit for your load